SPX
Maintenance: 1.Mixing system
The mixer won't start Causes of failure:
1) Stirring cannot be started;
2) The inverter is faulty;
Solution:
1) Check whether the lid is closed properly, check whether the lower limit travel switch of the stabilizer bar is damaged, if damaged, it must be replaced
2) Check if there is any program disorder in the frequency converter, and reset the frequency conversion program; if the frequency conversion is faulty, repair it in time:
2.Electronic control system
The power light is off
1)Check whether the on-off switch in the control box is closed;
2)Check whether the indicator light is normal;
3)Check whether the connecting wires of each component are firm;
4)Check the hand/stop/auto switch on the panel